Movincool Office Pro 60 Especificações

Consulte online ou descarregue Especificações para Aparelhos de ar condicionado "split system" Movincool Office Pro 60. Movincool Office Pro 60 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Technical Services Department
DSCA P/N: LA990009-1219 Third Issue: March 2003
GAC P/N: LA484007-1441 Printed in the U.S.A.
DENSO SALES CALIFORNIA, INC.
3900 Via Oro Avenue
Long Beach CA 90810-1868
800-264-9573 / 310-834-6352
www.movincool.com
OPERATION MANUAL
OFFICE PRO 60
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.
POSTAGE WILL BE PAID BY ADRESSEE
FIRST-CLASS MAIL PERMIT NO. 8390 LONG BEACH, CA
BUSINESS REPLY MAIL
DENSO SALES CALIFORNIA, INC. INC.
3900 VIA ORO AVENUE
LONG BEACH, CA 90810-9969
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
SECCIÓN EN ESPAÑOL
SECTION EN FRANÇAIS
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1 - OPERATION MANUAL

Technical Services DepartmentDSCA P/N: LA990009-1219 Third Issue: March 2003GAC P/N: LA484007-1441 Printed in the U.S.A.DENSO SALES CALIFORNIA, INC.39

Página 2 - LIMITED WARRANTY

INSTALLATIONChoosing an Installation SiteCAUTION: Following are some precautions to consider beforechoosing your installation site. Please review car

Página 3

INSTALLATION (cont.)Moving the UnitUnlock the casters and push the MovinCool unit, using the side handles,to a flat, level surface and set the casters

Página 4

INSTALLATION (cont.)Plugging in the Unit• Check the prongs and surface of the power cord plug for dust/dirt. Ifdust and/or dirt are present, wipe off

Página 5 - TABLE OF CONTENTS

FEATURESOP60 Features• An electronic control panel which allows the user to control theunit’s operation easily.• Dual fan speeds (either High or Low)

Página 6

TANKFULLSET POINTFCROOM TEMPAMPMSET TEMP CLOCK/TIMERFAN ON/OFFCOOL ON/OFF PROGRAMOffice Pro 60SETSTART TIMEEND TIMESET CLOCKRUNHRS MIN654321OPERATIONC

Página 7 - FOREWORD

OPERATION (cont.)Control Panel (Cont.)➆ Temperature Scale Illuminates to indicate the currentLED temperatures being displayed areeither in °C or °F; a

Página 8

OPERATION (cont.)Operating in COOL Mode➀ The unit can be operated in COOL mode by pressing the COOLON/OFF button (LED illuminates).NOTE: In COOL mode

Página 9 - INVENTORY

OPERATION (cont.)How to Set a Program➀ Setting a START TIMEPress the Program SET button. The Program SET button and STARTTIME LEDs will illuminate. Pr

Página 10 - INSTALLATION

OPERATION (cont.)How to Set a Program (Cont.)NOTE:• The unit will return to the previous mode if a program is turnedoff while it is running.• The Prog

Página 11 - INSTALLATION (cont.)

OPERATION (cont.)Operating ModesOffice Pro 60 operates in 2 modes, FAN Only and COOL. When in FANOnly mode, the unit circulates the surrounding air. W

Página 12

LIMITED WARRANTYDENSO SALES CALIFORNIA, INC. ("DENSO") warrants its MOVINCOOLProducts only to the extent stated in its official written warr

Página 13 - FEATURES

OPERATION (cont.)Emptying the Drain Tank (If equipped)During COOL mode, condensate will accumulate in the drain tank.When the drain tank becomes full,

Página 14 - OPERATION

ABOPERATION (cont.)Drain PumpA drain pump is included to allow continuous operation and to eliminatethe need for a drain tank.• When the water collect

Página 15 - OPERATION (cont.)

HOSE INSTALLATIONNote: The OP60 is equipped with a20 foot (6 m) hose.Connect the 20 foot (6 m) hose tothe drain outlet spout and feed itthrough the gr

Página 16

DAILY INSPECTION & MAINTENANCEEmptying the Drain TankTo empty the drain tank, refer to instructions, page 14.Cleaning the Air FiltersClean the air

Página 17

DAILY INSPECTION & MAINTENANCE (cont.)Cleaning Method➀ Remove dust from the elementwith a vacuum cleaner, or rinsein cold or lukewarm water. If th

Página 18

TROUBLESHOOTINGOffice Pro 60 Self-Diagnostic CodesSelf-Diagnostic Codes will be displayed on the Control Board underthe following conditions:TANKFULLS

Página 19

TECHNICAL SPECIFICATIONSITEM/FEATURES OFFICE PRO 60Rating Conditionsdry bulb 95º F (35º C)wet bulb 83º F (28.2º C)humidity 60%Specificationspower freq

Página 20

LIMITED WARRANTYDENSO SALES CALIFORNIA, INC. ("DENSO") warrants its MOVINCOOLProducts only to the extent stated in its official written warr

Página 21

Technical Services DepartmentDSCA P/N: LA990009-1219 Third Issue: March 2003GAC P/N: LA484007-1441 Printed in the U.S.A.DENSO SALES CALIFORNIA, INC.39

Página 22 - DRAIN HOSE

OPERATION MANUALOFFICE PRO 60

Página 24

TABLE OF CONTENTSFOREWORD ... 1Definition of Terms ...

Página 26 - TECHNICAL SPECIFICATIONS

FOREWORDCongratulations on purchasing the MovinCool portable air conditioner.This manual explains how to assemble, install and operate theMovinCool Of

Página 27

GENERAL WARNINGS & CAUTIONS• All electrical work, if necessary, should only be performed byqualified electrical personnel. Repair to electrical co

Página 28

INVENTORYAfter unpacking your MovinCool unit, please check to make sure youhave the following items:•Office Pro 60 MovinCool Unit (1)• Operation Manua